Chlorine Measuring Instrument - List of Manufacturers, Suppliers, Companies and Products

Chlorine Measuring Instrument Product List

1~7 item / All 7 items

Displayed results

Low concentration pH/free chlorine/total chlorine meter / MF2PTM-7710H

The MF2PTM-7710H can measure low concentrations of free/total chlorine as well as pH. (0.00–5.00 mg/L; 6.5–8.5 pH)

The MF2PTM-7710H can measure low concentrations of free/total chlorine as well as pH (0.00–5.00 mg/L; 6.5–8.5 pH). It is used for checking applications where chlorine levels are extremely low, such as tap water, well water, pools/baths, building management, and factory wastewater. The dedicated reagents used for measurement can be selected according to the frequency of measurement. Additionally, this device allows for numerical verification and calibration using a validator (standard solution set). This ensures high accuracy and reliability, providing peace of mind.

  • Water quality/pH measuring device

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

High Concentration Free Chlorine / High Concentration Total Chlorine Measuring Device / MF2PTM-7734H

The MF2PTM-7734H is a portable digital residual chlorine meter that can measure high concentrations of free chlorine/total chlorine.

The MF2PTM-7734H is a portable digital residual chlorine meter that can measure high concentrations of free chlorine and total chlorine. In addition to measuring low concentrations of chlorine in drinking water and industrial wastewater, it can also measure low-concentration electrolyzed water with levels below 10 mg/L. The measurement uses DPD reagents specified by official methods, ensuring high reliability. Furthermore, the device can be verified and calibrated using a validator (standard solution set), which maintains high accuracy and reliability, providing peace of mind.

  • Other analytical equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Residual chlorine measuring device 'Photometer CL-2'

Stable measurement accuracy allows for the precise measurement of residual chlorine.

The "Photometer CL-2" is a digital residual chlorine measuring device equipped with highly convenient features. It can determine the residual chlorine concentration in water using the "spectrophotometric method." By using DPD Plus, it can measure free residual chlorine concentrations in the range of 0.00 to 5.00 mg/L. (When measuring total residual chlorine concentration, DPD No. 3 reagent is used in conjunction.) 【Features】 ■ Accurate and stable measurement function ■ Easy-to-read red LED display ■ Dustproof and waterproof structure *For more details, please download the PDF or feel free to contact us.

  • Water quality/pH measuring device
  • others
  • Measurement and analysis equipment leasing and rental

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Low concentration free chlorine measuring device / Model number MF2PTM-7701H

The MF2PTM-7701H is a portable digital residual chlorine meter that measures low concentrations of free chlorine (0.00 to 5.00 mg/L).

The MF2PTM-7701H is a portable digital residual chlorine meter that measures low concentrations of free chlorine (0.00 to 5.00 mg/L). It is used in a wide range of fields, including tap water/drinking water, well water, pools/baths, and building/facility management. It also plays a role in measuring residual chlorine for the prevention of Legionnaires' disease. The measurement uses DPD reagents specified by official methods, ensuring high reliability. Additionally, the device can be verified and calibrated with a validator (standard solution set), maintaining high accuracy and reliability for peace of mind.

  • Water quality/pH measuring device

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Low concentration free chlorine/total chlorine measuring device/model number MF2PTM-7711H

The MF2PTM-7711H measures low concentrations of free chlorine/total chlorine. Free chlorine is mainly measured to confirm the presence of residual chlorine.

The MF2PTM-7711H measures low concentrations of free chlorine/total chlorine. It is a single device that can measure free chlorine (to check for residual chlorine in drinking water, well water, pools/baths, building/facility management, etc.) as well as total chlorine (to check for minimal chlorine in factory wastewater, etc.). The measurement uses DPD reagents specified by official methods, ensuring high reliability. Additionally, it allows for numerical verification and calibration of the main unit using a validator (standard solution set). This ensures high accuracy and reliability, providing peace of mind.

  • Water quality/pH measuring device

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Residual chlorine tester "DPD test kit"

Easy and speedy! The color comparison plate and back panel can be removed for cleaning, keeping it hygienic and allowing for accurate measurements.

The "DPD Test Kit" is a residual chlorine measuring device that uses DPD reagents to determine the residual chlorine concentration in water within the range of 0 to 2.0 mg/L. By using separately sold colorimetric plates and reagents, it is possible to measure effective chlorine concentration and hydrogen ion concentration. It is useful for hygiene management in drinking water, pool water, bathtub water, and in food factories or cooking facilities, as well as for managing the concentration of diluted sodium hypochlorite solutions used for sterilization and disinfection of equipment and environments. 【Features】 - Easy and quick measurement using the single reagent "DPD Plus" - Total residual chlorine concentration can also be measured using "DPD No. 3 reagent" (measurement range: 0 to 2.0 mg/L) - By placing the water sample in the test tube for colorimetric plate correction, errors in water quality (concentration, color, etc.) can be corrected - The colorimetric plate and back plate can be removed and cleaned, allowing for hygienic maintenance and accurate measurements *For more details, please refer to the PDF document or feel free to contact us.

  • Environmental Survey

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Residual chlorine tester (DPD method)

We introduce a residual chlorine meter that requires only one reagent addition operation, making it easy to manage and economical.

The "Residual Chlorine Measuring Device" is a simple measurement method based on the reaction that produces a light reddish-purple color when DPD reagent is added to water containing residual chlorine, depending on the concentration of residual chlorine. The reagent addition operation is performed once. (For total residual chlorine measurement, separately sold potassium iodide is used.) It is an excellent method that clearly distinguishes between free residual chlorine and total residual chlorine. Additionally, the colorimetric plate is removable, making management easy and economical. 【Specifications】 ■ Measurement method: DPD method ■ Produces a light reddish-purple color depending on the residual chlorine concentration ■ Reagent addition operation is performed once ■ An excellent method that clearly distinguishes between free residual chlorine and total residual chlorine ■ The colorimetric plate is removable, making management easy and economical *For more details, please refer to the PDF document or feel free to contact us.

  • Other measuring instruments

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Search Keywords Related to Chlorine Measuring Instrument